The performance of vapor compression refrigeration cycles[26] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[27][dead link]

Be careful with HVAC change-outs.  Change-outs are only about 15-20% of the HVAC installation industry. Decrease HVAC installation cost by investing in new ductwork now if needed. Your ducts wear out too, and make sure that your ducts are in fantastic shape if you do this. Many contractors push this because it’s easy and cheap for them, with good pay-off. Do your research and replace them if you need to in order to avoid doing it later, as well as avoid potential health hazards from using old, broken ductwork.


An air conditioner's compressor contains a refrigerant. As it works, it sends this refrigerant through the system. As warm air blows across the coil that carries this refrigerant, the heat transfers to the refrigerant (cool always absorbs warm). A fan moves the cooled air through the ducting and out of vents that lead into the rooms of your house. The refrigerant returns to the compressor where the absorbed heat is moved outside. The refrigerant is then sent through the coil once again to continue the cycle.
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
I was disappointed with the pressure of a tub and shower that were plumbed with 1/2 supply lines (2nd floor). Could be low pressure from the street, but I want to replace with 5/8. Plus, I'd like to have 2 back to back showers, one inside and one outside. So, I had intended to bring a 1 supply to both, then branch up to valves and shower head with 5/8. Finally, I thought pressure from the street was typically 55 to 70 psi and I am concerned if pvc can take that.Any thoughts?
Indoor Coil -- The indoor coil is a heat transfer device. It absorbs the heat from the inside of the house and passes it on to the refrigerant and is pumped outside. Dust that builds up on the coil can hamper its ability to absorb heat. High heat transference coils use very thin metal. Airborne chemicals can cause corrosion which leads to leaks. The constant vibration of the compressor can also cause solder joints to weaken and leak. An indoor coil may operate for weeks with a tiny leak, and you may not notice the loss in performance right away. As soon as a leak is made known, it should be replaced or repaired immediately.

In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
Undertaking an AC installation in Fort Smith, AR? The first thing to remember is that your air conditioning unit will need repairs now and then to remain efficient. Granted, many repair emergencies can be avoided through proper maintenance procedures. When your AC fails we provide reliable, affordable repairs of the highest standards. Enhanced efficiency and longevity is the name of our game.
Installation: The old furnace is disconnected from the ductwork plenum, exhaust flue, gas and electrical hookups. In most cases, a new plenum must be made onsite or ordered from a local sheet metal fabricator. A new vent might be required too. The furnace is set and reconnected. Adjustments to the blower fan speed and burner are made to optimize furnace performance for your home and climate.
Brands like American Standard, Trane and Lennox cost the most. Goodman is the cheapest. The rest populate the middle of the spectrum. Here’s something to know: The quality among brands isn’t as great as price differences. The difference in prices reflect that some customers want “bargain” equipment to save cost and others want “premium” equipment they believe will run longer with less trouble. Therefore, each manufacturer has priced to meet consumer perception.

We have provided Arkansas families and businesses with quality HVAC products and services for 42 years. Offering reasonable rates and personalized service, we are a dedicated team of experts equipped to handle any service requirement. Your source for modern heating, cooling, and ventilation equipment and servicing, Wilson's Heating & Air Conditioning is the HVAC specialist in Van Buren.
If your compressor doesn’t have an overload button and you hear it humming or buzzing, poke a screwdriver or stick down through the top grille and try to spin the fan blades clockwise. If doing this gives the fan enough of a boost to get it going, the unit has a faulty capacitor that must be replaced. See How to Test and Replace an AC Run Capacitor, above.
×