Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).
My Carrier furnace occasionally (one-two times a day) does not start. It shows error code 15 ("BLOWER MOTOR LOCKOUT -This status code indicates the blower failed to reach 250 RPM or the blower failed to communicate to the variable speed furnace control within 30 seconds after being turned ON in two successive heating cycles."). However, when I turn off and on the furnace power switch it starts and runs fine for a while. Sometimes it runs fine all day, but does not start only once in the evening or in the night. It is 13 years old I was thinking to replace whole thing if repair cost is too high. But I am not ready to pay $10,000. 
Installation: The old furnace is disconnected from the ductwork plenum, exhaust flue, gas and electrical hookups. In most cases, a new plenum must be made onsite or ordered from a local sheet metal fabricator. A new vent might be required too. The furnace is set and reconnected. Adjustments to the blower fan speed and burner are made to optimize furnace performance for your home and climate.

HVAC System Quality Installation Contractor Checklist -- This checklist identifies all of the steps the contractor has taken for the Energy Star Certification and identifies what work the contractor has done. If the system is later modified, this checklist can help identify what was done to proper Energy Star specifications and what was added later that may not meet the requirements.


I was disappointed with the pressure of a tub and shower that were plumbed with 1/2 supply lines (2nd floor). Could be low pressure from the street, but I want to replace with 5/8. Plus, I'd like to have 2 back to back showers, one inside and one outside. So, I had intended to bring a 1 supply to both, then branch up to valves and shower head with 5/8. Finally, I thought pressure from the street was typically 55 to 70 psi and I am concerned if pvc can take that.Any thoughts?

This company deserves more than five stars. They didn't just replace my heater and air conditioner, they built me a new system for my house. Going above and beyond is a understatement. Steve's staff were 2 of the nicest workers I've come across in a long time. Friendly, knowledgeable, and very clean. Truly a top rated company. Thanks Steve.   Great job.


In addition to the information below, see these two articles for the general care and maintenance of your air conditioner: Preparing Your Air Conditioner for Summer and How to Replace Furnace & AC Filters. Most noteworthy, you should replace the filters at least twice a year, before the heating and cooling seasons. For information on furnace problems, please see Furnace Not Working.
×